Part Number Hot Search : 
2SB1037 EP9154 2058783 BC857A LM10V33 LM10V33 00020 2058783
Product Description
Full Text Search
 

To Download F-513320GNY-LY-AA Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 OPTREX
LCD Module Technical Specification t4
U
.
om c
First Edition
Mar 16, 2001
Final Revision
Type No.
w
w
w
.D
a
S aF-51320GNY-LY-AA t
ee h
******
Approved by (Production Div.)
Checked by (Quality Assurance Div.)
Checked by (Design Engineering Div.)
Prepared by (Production Div.)
Table of Contents
1. General Specifications.................................................................................................................................. 2 2. Electrical Specifications............................................................................................................................... 3 3. Optical Specifications ................................................................................................................................. 12 4. I/O Terminal.................................................................................................................................................... 14 5. Test................................................................................................................................................................... 17 6. Appearance Standards ............................................................................................................................... 18 7. Code System of Production Lot............................................................................................................... 21 8. Type Number.................................................................................................................................................. 21 9. Applying Precautions .................................................................................................................................. 21 10. Precautions Relating Product Handling................................................................................................ 22 11. Warranty ........................................................................................................................................................ 23
Revision History
Rev. Date
w
w
w
.D
Page
t a
S a
e h
t e
U 4
.c
m o
Comment
F-51320GNY-LY-AA (AA) No. 2001-0047
OPTREX CORPORATION
w
w
w
.D
at
Sh a
et e
4U
.
om c
Page 1/23
1. General Specifications
Operating Temp. Storage Temp. Dot Pixels Dot Size Dot Pitch Viewing Area Outline Dimensions
: : : : : : :
min. 0C ~max. 50C min. -20C ~max. 70C 128 (W) 0.48 (W) 0.50 (W) 66.8 (W)
x
64 (H) dots 0.48 (H) mm 0.50 (H) mm 35.5 (H) mm
x
x
x
89.7 (W) x 49.8* (H) x (11.8)** (D) mm * Without FPCUV ** Without Fook of LED Backlight 43.5g max. NTD-20526 ( STN / Yellow-mode / Transmissive ) 6:00 8-bit parallel data transfer LED Backlight / Yellow-green Dimensional Outline UE-310360A
Weight LCD Type
: :
Viewing Angle Data Transfer Backlight Drawings
: : : :
F-51320GNY-LY-AA (AA) No. 2001-0047
OPTREX CORPORATION
Page 2/23
2. Electrical Specifications
2.1. Absolute Maximum Ratings GND=0V Parameter Supply Voltage (Logic) Supply Voltage (Booster Circuit) Supply Voltage 1 (LCD Drive) Input Voltage Symbol VDD-GND VDD-GND V5,VOUT VIN Conditions With Triple (In case of 5V) With Quad (In case of 3V) Min. -0.3 -6.0 -4.5 -18.0 -0.3 Max. 7.0 +0.3 +0.3 +0.3 VDD+0.3 Units V V V V
2.2. DC Characteristics Ta=25C, GND=0V Parameter Supply Voltage (Logic) Supply Voltage (LCD Drive) "High" Level Input Voltage "Low" Level Input Voltage "High" Level Output Voltage "Low" Level Output Voltage Supply Current Symbol VDD-GND VDD-V5 VIH VIL VOH VOL IDD IOH=-0.1mA IOL=0.1mA VDD-GND=5.0V Conditions With Triple With Quad Min. 4.5 2.8 Shown in 3.1 0.8xVDD GND 0.8xVDD GND 1.08 VDD 0.2xVDD VDD 0.2xVDD 1.62 Typ. Max. 5.5 3.2 V V V V V MA Units V
F-51320GNY-LY-AA (AA) No. 2001-0047
OPTREX CORPORATION
Page 3/23
2.3. AC Characteristics 2.3.1. Read/Write Operation Sequence (80 series CPU) VDD=5.0V10% Parameter Address Setup Time Address Hold Time System Cycle Time Control Low Pulse Width WRITE READ Control High Pulse Width WRITE READ Data Setup Time Data Hold Time RD Access Time Output Disable Time Symbol Min. 0 0 166 30 70 30 30 30 10 5 Max. 70 50 Units ns ns ns ns ns ns ns ns ns ns ns VDD=2.7~4.5V Parameter Address Setup Time Address Hold Time System Cycle Time Control Low Pulse Width WRITE READ Control High Pulse Width WRITE READ Data Setup Time Data Hold Time RD Access Time (CL=100pF) Output Disable Time Symbol Min. 0 0 300 60 120 60 60 40 15 10 Max. 140 100 Units ns ns ns ns ns ns ns ns ns ns ns
tAW8 tAH8 tCYC8 tCCLW tCCLR tCCHW tCCHR tDS8 tDH8 tACC8 tOH8
tAW8 tAH8 tCYC8 tCCLW tCCLR tCCHW tCCHR tDS8 tDH8 tACC8 tOH8
F-51320GNY-LY-AA (AA) No. 2001-0047
OPTREX CORPORATION
Page 4/23
tAH8 A0
CS1 (CS2="1") tAW8 tCCLR, tCCLW WR, RD tf D0~D7 (WRITE) tACC8 D0~D7 (READ) tOH8 tDS8 tr tCCHR, tCCHW tDH8 tCYC8
F-51320GNY-LY-AA (AA) No. 2001-0047
OPTREX CORPORATION
Page 5/23
2.3.2. Read/Write Operation Sequence (68 series CPU) VDD=5.0V10% Parameter Address Setup Time Address Hold Time System Cycle Time Data Setup Time Data Hold Time Access Time (CL=100pF) Output Disable Time Enable High Pulse Width READ WRITE Enable Low Pulse Width READ WRITE Symbol Min. 0 0 166 30 10 10 70 30 30 30 Max. 70 50 Units ns ns ns ns ns ns ns ns ns ns ns VDD=2.7~4.5V Parameter Address Setup Time Address Hold Time System Cycle Time Data Setup Time Data Hold Time Access Time (CL=100pF) Output Disable Time Enable High Pulse Width READ WRITE Enable Low Pulse Width READ WRITE Symbol Min. 0 0 300 40 15 10 120 60 60 60 Max. 140 100 Units ns ns ns ns ns ns ns ns ns ns ns
tAH6 tAW6 tCYC6 tDS6 tDH6 tACC6 tOH6 tEWHR tEWHW tEWLR tEWLW
tAH6 tAW6 tCYC6 tDS6 tDH6 tACC6 tOH6 tEWHR tEWHW tEWLR tEWLW
F-51320GNY-LY-AA (AA) No. 2001-0047
OPTREX CORPORATION
Page 6/23
CS1 (CS2="1") t CYC6 tEWLR, tEWLW
E
tEWHR, tEWHW tAW6 tr tf tAH6
WR,RD tDS6 D0D7 (WRITE) tACC6 D0D7 (READ) tOH6 tDH6
F-51320GNY-LY-AA (AA) No. 2001-0047
OPTREX CORPORATION
Page 7/23
2.3.3. Display Control Timing Characteristics Reset Input Timing Parameter Reset time Reset "L" Pulse Width Reset Input Timing Parameter Reset time Reset "L" Pulse Width Symbol Min. 1 Typ. Max. 1 Symbol Min. 0.5 Typ. Max. 0.5 VDD=5.010% Units ns s VDD=2.74.5V Units ns s
tR tRW
tR tRW
Output Timing Parameter FR Delay Time Output Timing Parameter FR Delay Time Symbol Min. Typ. 20 Max. 80 Symbol Min. Typ. 10 Max. 40
VDD=5.010% Units ns VDD=2.74.5V Units ns
tDFR
tDFR
Note 1 :Valid only when the master mode is selected. Note 2:All timing is based on 20% and 80% of Vss.
RES
tRW
Internal states During reset
tR
Reset complete
F-51320GNY-LY-AA (AA) No. 2001-0047
OPTREX CORPORATION
Page 8/23
F-51320GNY-LY-AA (AA) No. 2001-0047
OPTREX CORPORATION
Page 9/23
F-51320GNY-LY-AA (AA) No. 2001-0047
OPTREX CORPORATION
Page 10/23
2.4. Lighting Specifications 2.4.1. Absolute Maximum Ratings Ta=25C (1Unit) Parameter Foward Current Reverse Voltage LED Power Dissipation Symbol IF VR PD Conditions Note 1 Min. Typ. Max. 280 10 1.34 Units mA V W
Note 1 : Refer to the foward current derating curve.
IF (mA) 280
191
0
25
50
Ta (C)
+
-
2.4.2. Operating Characteristics Ta=25C Parameter Foward Voltage Luminance of Backlight Surface Symbol VF L Conditions IF=10mA IF=10mA Min. 60.0 Typ. 4.3 Max. 4.8 Units V cd/m2
F-51320GNY-LY-AA (AA) No. 2001-0047
OPTREX CORPORATION
Page 11/23
3. Optical Specifications
3.1. LCD Driving Voltage Parameter Recommended LCD Driving Voltage Note 1 Note 1 : VDD-V5 Symbol Conditions Ta= 0C Ta=25C Ta=50C Min. 8.4 8.2 Typ. 9.0 Max. 9.7 9.6 Units V V V
Voltage (Applied actual waveform to LCD Module) for the best contrast. The range of minimum and maximum shows tolerance of the operating voltage. The specified contrast ratio and response time are not guaranteed over the entire range.
3.2. Optical Characteristics Ta=25C, 1/65 Duty, 1/7 Bias, VD=9.0V (Note 4), = 0, = - Parameter Contrast Ratio Viewing Angle Response Time Note 1 : Rise Note 2 Decay Note 3 TON TOFF Note 1 Symbol CR Conditions = 0, = - Min. Typ. 4.5 Max. Units
Shown in 3.3 200 90 300 180 ms ms
Contrast ratio is definded as follows. CR = LOFF / LON LON : Luminance of the ON segments LOFF : Luminance of the OFF segments Mesuring Spot=3mm Note 2 : The time that the luminance level reaches 90% of the saturation level from 0% when ON signal is applied. Note 3 : The time that the luminance level reaches 10% of the saturation level from 100% when OFF signal is applied. Note 4 : Definition of Driving Voltage VD Assuming that the typical driving waveforms shown below are applied to the LCD Panel at 1/A Duty - 1/B Bias ( A : Duty Number, B : Bias Number ). Driving voltage VD is definded as follows. VD = (Vth1+Vth2) / 2 Vth1 : The voltage VO-P that should provide 50% of the saturation level in the luminance at the segment which the ON signal is applied to. Vth2 : The voltage VO-P that should provide 50% of the saturation level in the luminance at the segment which the OFF signal is applied to.
VO-P
( B-2 )x V O-P / B 1 / ( f F xA ) 1 / fF


F-51320GNY-LY-AA (AA) No. 2001-0047
OPTREX CORPORATION
Page 12/23
3.3. Definition of Viewing Angle and Optimum Viewing Area *Point * shows the point where contrast ratio is measured. : = 0, = - *Driving condition : 1/65 Duty, 1/7 Bias, VD=9.0V, fF=80Hz 90 135 45
180 ( = 0)
90
10 20 30 40 50
180 225 270
0
315 270
*Area
shows typ. CR2 (Mesuring Spot=3mm)
3.4. System Block Diagram
Temperature Chamber Rotation Table ( , ) Photometer #1980A WB
LCD Optical Fiber
Computer
Control Unit & Waveform Generator Halogen bulb
F-51320GNY-LY-AA (AA) No. 2001-0047
OPTREX CORPORATION
Page 13/23
4. I/O Terminal
4.1. Pin Assignment CN1 No. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. Symbol NC CS1 RES A0 WR RD D0 D1 D2 D3 D4 D5 D6 D7 VDD GND VOUT CAP3CAP1+ CAP1CAP2CAP2+ V1 V2 V3 V4 V5 VR C86 Level H/L H/L H/L H/L H/L H/L H/L H/L H/L H/L H/L H/L H/L H/L Non-connection Chip Select Signal L : Active Reset Signal L : Reset H : D0~D7 are Display Data L : D0~D7 are Instructions Write Signal L : Active Read Signal L : Active Data Bus Line Data Bus Line Data Bus Line Data Bus Line Data Bus Line Data Bus Line Data Bus Line Data Bus Line Power Supply for Logic Power Supply ( 0V, GND ) DC/DC Voltage Converter Output DC/DC Voltage Converter Capacitor 1 Negative Connection DC/DC Voltage Converter Capacitor 1 Positive Connection DC/DC Voltage Converter Capacitor 1 Negative Connection DC/DC Voltage Converter Capacitor 2 Negative Connection DC/DC Voltage Converter Capacitor 2 Positive Connection Power Supply for LCD Drive V1 = 1/7,V5 Power Supply for LCD Drive V2 = 2/7,V5 Power Supply for LCD Drive V3 = 5/7,V5 Power Supply for LCD Drive V4 = 6/7,V5 Power Supply for LCD Drive V5,VOUT Voltage Adjustment Pin Interface Mode Select Signal H : 68 series L : 80 series Function
F-51320GNY-LY-AA (AA) No. 2001-0047
OPTREX CORPORATION
Page 14/23
30.
IRS
H/L
This terminal selects the resistors for the V5 voltage level adjustment. IRS="H" :Use the internal resistors IRS="H" :Do not use the internal resistors. The V5 voltage level is requlated by an external resistive voltage divider attached
4.2. Example of Power Supply
MODULE
VDD GND C1
VDD GND VOUT CAP3Booster Circuit
LSI
C2 C3
CAP1+ CAP1CAP2CAP2+
C3
C5 C6 C7 C8
V1 V2 V3 V4 V5 R2 LCD Driver
C9
R1 VR
F-51320GNY-LY-AA (AA) No. 2001-0047
OPTREX CORPORATION
Page 15/23
4.3.Block Diagram
CS1 RES A0 WR RD D0 D1
COM 32
D2
D3 D4 Control LSI D5 D6 1565DBB D7 VDD GND VOUT CAP3CAP1+ CAP1CAP2CAP2+ V1 V2 V3 V4 V5 VR C86 IRS
COM 32 SEG 128
LCDP 128 x 64 dots
F-51320GNY-LY-AA (AA) No. 2001-0047
OPTREX CORPORATION
Page 16/23
5. Test
No change on display and in operation under the following test condition. No. 1 2 3 4 5 6 Parameter High Temperature Operating Low Temperature Operating High Temperature Storage Low Temperature Storage Damp Proof Test Temperature Cycle Test Conditions 50C2C, 96hrs (operation state) 0C2C, 96hrs (operation state) 70C2C, 96hrs -20C2C, 96hrs 40C2C, 90~95%RH, 96hrs 5 Cycle
70C 25C -20 C
30Min 10Min 30Min 10Min 1 Cycle
Notes 3 4 5 4, 5 4, 5 4
The function test shall be conducted after 1 hours storage at the normal temperature and 7 Shock Test To be measured after dropping from 60cm high on the concrete surface in packing state.
Dropping method corner dropping F E B 60cm Concrete Surface G D A C A corner : once Edge dropping B,C,D edge : once Face dropping E,F,G face : once
Note 1 : Unless otherwise specified, tests will be conducted under the following condition. Temperature : 205 Humidity : 655%RH Note 2 : Unless otherwise specified, tests will be not conducted under functioning state. Note 3 : It should be checked at the actual driving condition under the high temperature. Note 4 : No dew condensation to be observed. Note 5 : The function test shall be conducted after 4 hours storage at the normal temperature and humidity after removed from the test chamber. Note 6 : Vibration test will be conducted to the product itself without putting it in a ontainer. Note 7 : No air bubbles and no color variation on display more than 24 hours after the test.
F-51320GNY-LY-AA (AA) No. 2001-0047
OPTREX CORPORATION
Page 17/23
6. Appearance Standards
6.1. Inspection conditions The LCD shall be inspected under 40W white fluorescent light. The distance between the eyes and the sample shall be more than 30cm. All directions for inspecting the sample should be within 45against perpendicular line.
45
6.2. Definition of applicable Zones
X
X
X
A Zone B Zone X C Zone X : Maximum Seal Line
A Zone : Active display area B Zone : Out of active display area ~ Maximum seal line C Zone : Rest parts A Zone + B Zone = Validity viewing area
F-51320GNY-LY-AA (AA) No. 2001-0047
OPTREX CORPORATION
Page 18/23
6.3. Standards No. 1 Parameter Black and White Spots, Foreign Substances Dimension (mm) D 0.1 0.1 < D 0.2 0.2 < D 0.25 0.25< D 0.3 0.3 < D D = ( Long + Short ) / 2 (2) Line Shape Zone X (mm) 2.0 L 1.0 L Y (mm) 0.03 W 0.05 W 0.1 W 0.1 < W A * 3 3 Acceptable Number B * 3 3 In the same way (1) * : Disregard C * * * (1) Round Shape Zone A * 3 2 0 0 * : Disregard Acceptable Number B * 5 3 1 0 C * * * * * Criteria
X : Length Y : Width
Total defects shall not exceed 5. 2 Air Bubbles (between glass & polarizer) Dimension (mm) D 0.3 0.3 < D 0.4 0.4 < D 0.6 0.6 < D * : Disregard Total defects shall not exceed 3. Zone A * 3 2 0 Acceptable Number B * * 3 0 C * * * *
F-51320GNY-LY-AA (AA) No. 2001-0047
OPTREX CORPORATION
Page 19/23
No. 3
Parameter The Shape of Dot (1) Dot Shape (with Dent)
0.15
Criteria
As per the sketch of left hand.
(2) Dot Shape (with Projection)
Should not be connected to next dot.
(3) Pin Hole
X
(X+Y) / 2 0.2mm
Y
(Less than 0.1mm is no counted.)
(4) Deformation
Y
(X+Y) / 2 0.2mm
X
Total acceptable number : 1/dot, 5/cell (Defect number of (4) : 1pc.) 4 5 Polarizer Scratches Polarizer Dirts Not to be conspicuous defects. If the stains are removed easily from LCDP surface, the module is not defective. 6 Complex Foreign Substance Defects 7 Distance between Different Foreign Substance Defects Black spots, line shaped foreign substances or air bubbles between glass & polarizer should be 5pcs maximum in total. D 0.2 : 20mm or more 0.2 < D : 40mm or more
F-51320GNY-LY-AA (AA) No. 2001-0047
OPTREX CORPORATION
Page 20/23
7. Code System of Production Lot
The production lot of module is specified as follows. The production lot of module is specified some of the following.
Sub Number (In case of divide lot) Production Date (01,02,03~) Production Month (1~9, X, Y, Z) Production Year (Lower 1 digit) Lot different and chip loading day different (A~V)
8. Type Number
The type number of module is specified as follows. F-51320GNY-LY-AA Stamp
9. Applying Precautions
Please contact us when questions and/or new problems not specified in this specifications arise.
F-51320GNY-LY-AA (AA) No. 2001-0047
OPTREX CORPORATION
Page 21/23
10. Precautions Relating Product Handling
The Following precautions will guide you in handling our product correctly. 1) Liquid crystal display devices 1. The liquid crystal display device panel used in the liquid crystal display module is made of plate glass. Avoid any strong mechanical shock. Should the glass break handle it with care 2. The polarizer adhering to the surface of the LCD is made of a soft material. Guard against scratching it. 2) Care of the liquid crystal display module against static electricity discharge. 1. When working with the module, be sure to ground your body and any electrical equipment you may be using. We strongly recommend the use of anti static mats ( made of rubber ), to protect work tables against the hazards of electrical shock. 2. Avoid the use of work clothing made of synthetic fibers. We recommend cotton clothing or other conductivity-treated fibers. 3. Slowly and carefully remove the protective film from the LCD module, since this operation can generate static electricity. 3) When the LCD module alone must be stored for long periods of time: 1. Protect the modules from high temperature and humidity. 2. Keep the modules out of direct sunlight or direct exposure to ultraviolet rays. 3. Protect the modules from excessive external forces. 4) Use the module with a power supply that is equipped with an overcurrent protector circuit, since the module is not provided with this protective feature. 5) Do not ingest the LCD fluid itself should it leak out of a damaged LCD module. Should hands or clothing come in contact with LCD fluid, wash immediately with soap. 6) Conduc1tivity is not guaranteed for models that use metal holders where solder connections between the metal holder and the PCB are not used. Please contact us to discuss appropriate ways to assure conductivity. 7) For models which use CFL: 1. High voltage of 1000V or greater is applied to the CFL cable connector area. Care should be taken not to touch connection areas to avoid burns. 2. Protect CFL cables from rubbing against the unit and thus causing the wire jacket to become worn. 3.The use of CFLs for extended periods of time at low temperatures will significantly shorten their service life. 8) For models which use touch panels: 1.Do not stack up modules since they can be damaged by components on neighboring modules. 2.Do not place heavy objects on top of the product. This could cause glass breakage. 9) For models which use COG,TAB,or COF: 1.The mechanical strength of the product is low since the IC chip faces out unprotected from the rear. Be sure to protect the rear of the IC chip from external forces. 2.Given the fact that the rear of the IC chip is left exposed, in order to protect the unit from electrical damage, avoid installation configurations in which the rear of the IC chip runs the risk of making any electrical contact.
F-51320GNY-LY-AA (AA) No. 2001-0047
OPTREX CORPORATION
Page 22/23
10) Models which use flexible cable, heat seal, or TAB: 1.In order to maintain reliability, do not touch or hold by the connector area. 2.Avoid any bending, pulling, or other excessive force, which can result in broken connections.
11. Warranty
This product has been manufactured to your company's specifications as a part for use in your company's general electronic products. It is guaranteed to perform according to delivery specifications. For any other use apart from general electronic equipment, we cannot take responsibility if the product is used in medical devices, nuclear power control equipment, aerospace equipment, fire and security systems, or any other applications in which there is a direct risk to human life and where extremely high levels of reliability are required. If the product is to be used in any of the above applications, we will need to enter into a separate product liability agreement. 1. We cannot accept responsibility for any defect, which may arise from additional manufacturing of the product (including disassembly and reassembly), after product delivery. 2. We cannot accept responsibility for any defect, which may arise after the application of strong external force to the product. 3. We cannot accept responsibility for any defect, which may arise due to the application of static electricity after the product has passed your company's acceptance inspection procedures. 4. When the product is in CFL models, CFL service life and brightness will vary according to the performance of the inverter used, leaks, etc. We cannot accept responsibility for product performance, reliability, or defect, which may arise. 5. We cannot accept responsibility for intellectual property of a third party, which may arise through the application of our product to your assembly with exception to those issues relating directly to the structure or method of manufacturing of our product. 6. Optrex will not be held responsible for any quality guarantee issue for defect products judged as Optrex-origin longer than 2 (two) years from Optrex production or 1(one) year from Optrex, Optrex America, Optrex Europe, Display LC delivery which ever comes later.
F-51320GNY-LY-AA (AA) No. 2001-0047
OPTREX CORPORATION
Page 23/23


▲Up To Search▲   

 
Price & Availability of F-513320GNY-LY-AA

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X